Calipers
Micrometers
Soldering Irons
Calibrated Weights
Digital Scale
MyDAQ & Breadboard
Thermocouple (Type K & J)
Thermocouple Reader
Load Cell
Strain Guage
Please ask a Student Lab Tutor if you would like to check out any equipment!
ENGR 108
Materials Science/Instrumentation
ENGR 110
Thermofluids
Capable of tensile and compression testing
50kN load capacity
Programmable testing procedures
Can export test data to .csv file
Grip dimensions 1" x .45" x 2"
Tensile Tester Safety:
Wear Safety glasses and cut resistant gloves
Wear clothes-toed shoes, and avoid loose clothing
Do not wear headphones and keep hair tied back
Only place approved items in the tensile tester
Ask the Student Lab Tutors (SLTs) for help with the software and to verify safety measures
IT Series
Adjustable weights up to 1556g
Maximum sample size .5" x 1" x 4"
Impact Tester Safety:
Wear Safety glasses and cut resistant gloves
Wear clothes-toed shoes, and avoid loose clothing
Do not wear headphones and keep hair tied back
Only one person is permitted in the working radius (5ft within the Impact Tester) during testing.
60kN, 100kN, and 150kN major loads
Rockwell (HRC) and Brinell (BHN) hardness capabilities
Vertical Capacity: 12"
Max temperature of 2250 F (1232.2 C)
240 V (AC usage), 39 Amps
16" x 20" x 12" chamber
Electric Furnace Safety:
Wear the proper heat insulated gloves, helmet, and jacket (provided)
Wear clothes-toed shoes, and long pants
Do not wear headphones and keep hair tied back
Only place approved items in the furnace
7' x 2' x 2' testing space
Infinitely adjustable wind speed between 2.29 m/s and 68.6 m/s
Strain gages to measure lift and drag forces
Airflow is adjustable to at least 0.14 m^3/s
Switchable heating up to 4kW
Bulb sensors with 0 to 100% RH measurement capability
7 Liter Capacity
-20 to 200 C or -4 -to 392 F Range
Model (AD07R-20-A11B)
15, -15, 5, Ext V power supply
Measures up to +-10 V signals
Digital Multimeter
Schedule two weeks in advance
8,000 Calorie limit
30 atm max pressure
1.5 gram cap limit on sample material
Adjustable Vanes, forward, backward, and straight
Flowmeter, Pressure Inlet and Outlet, Temperature, and Torque measurements
Instruction Manual